Files
rigdoctor/tests/test_displays.py
T
jessey b006fa6b8d
tests / core (pull_request) Successful in 12s
tests / gui-smoke (pull_request) Successful in 27s
feat(displays): monitors w/ resolution+refresh in Inventory; flag sub-max refresh in Health — 0.39.0
New core/displays.py reads connected monitors via GNOME Mutter DisplayConfig over
D-Bus (busctl --json; works on X11 + Wayland), falling back to xrandr on other X11
desktops. Inventory's Display section now lists each monitor's resolution + current
refresh (e.g. 'DP-1 · Samsung LC34G55T: 3440x1440 @ 165 Hz'). System Health
(check_displays) flags a monitor running below its max refresh AT THE CURRENT
resolution (e.g. 165 Hz panel set to 60 Hz) — never suggests lowering resolution.
+tests (Mutter JSON + xrandr parsers, health check).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 16:55:33 +02:00

68 lines
2.5 KiB
Python

"""Tests for display detection (Mutter D-Bus JSON + xrandr parsers)."""
import unittest
from rigdoctor.core import displays
# Minimal Mutter GetCurrentState (busctl --json) shape: current mode is 60 Hz, panel max 165 Hz.
_MUTTER_60 = (
'{"type":"x","data":[1,[[["DP-1","SAM","LC34G55T","S"],['
'["3440x1440@60",3440,1440,60.0,1.0,[1.0],{"is-current":{"type":"b","data":true}}],'
'["3440x1440@165",3440,1440,165.0,1.0,[1.0],{"is-preferred":{"type":"b","data":true}}]'
'],{}]],[],{}]}'
)
_MUTTER_MAX = (
'{"type":"x","data":[1,[[["DP-1","SAM","LC34G55T","S"],['
'["3440x1440@165",3440,1440,165.0,1.0,[1.0],{"is-current":{"type":"b","data":true}}],'
'["3440x1440@60",3440,1440,60.0,1.0,[1.0],{}]'
'],{}]],[],{}]}'
)
_XRANDR_60 = """Screen 0: minimum 8 x 8, current 3440 x 1440, maximum 16384 x 16384
DP-1 connected primary 3440x1440+0+0 (normal left inverted right x axis y axis) 800mm x 335mm
3440x1440 60.00*+ 165.00 100.00
2560x1440 165.00 60.00
HDMI-1 disconnected (normal left inverted right x axis y axis)
"""
class MutterParseTests(unittest.TestCase):
def test_parses_and_flags_higher_refresh(self):
mons = displays._parse_mutter(_MUTTER_60)
self.assertEqual(len(mons), 1)
m = mons[0]
self.assertEqual(m.connector, "DP-1")
self.assertEqual(m.name, "Samsung LC34G55T") # PNP code SAM mapped
self.assertEqual((m.width, m.height), (3440, 1440))
self.assertEqual(round(m.refresh), 60)
self.assertEqual(round(m.max_refresh), 165)
self.assertTrue(m.can_go_faster)
def test_at_max_is_not_flagged(self):
m = displays._parse_mutter(_MUTTER_MAX)[0]
self.assertEqual(round(m.refresh), 165)
self.assertFalse(m.can_go_faster)
def test_garbage_returns_empty(self):
self.assertEqual(displays._parse_mutter("not json"), [])
self.assertEqual(displays._parse_mutter("{}"), [])
class XrandrParseTests(unittest.TestCase):
def test_current_and_max_refresh(self):
mons = displays._parse_xrandr(_XRANDR_60)
self.assertEqual(len(mons), 1) # disconnected output ignored
m = mons[0]
self.assertEqual(m.connector, "DP-1")
self.assertEqual((m.width, m.height), (3440, 1440))
self.assertEqual(round(m.refresh), 60)
self.assertEqual(round(m.max_refresh), 165)
self.assertTrue(m.can_go_faster)
def test_empty_returns_empty(self):
self.assertEqual(displays._parse_xrandr(""), [])
if __name__ == "__main__":
unittest.main()